产品资料

NRP-Z85 功率探头

如果您对该产品感兴趣的话,可以 sendmsg
产品名称: NRP-Z85 功率探头
产品型号: NRP-Z85
产品展商: 德国罗德施瓦茨
产品文档: 无相关文档

简单介绍

NRP-Z85 功率探头 NRP-Z85 功率探头 无论在实验室还是在生产线,微波功率计R&S NRP都是你正确的选择。新颖的R&S NRP系列功率计的通用性主要归因于新近开发的功率探头。这些探头是智能的独立仪器,他们与基本单元通讯,或经由数字接口与一个pc机通信。现在****实现的智能传感技术,建立了根据通用性和准确性要求的新标准。 如果说功率


NRP-Z85 功率探头  的详细介绍
  • R&S®NRP-Z R&S®NRP-Z Power Sensors
    Power Sensors

    For operation with R&S®NRP2 base unit or via USB on a Laptop/PC

     

     

Three-Path Diode Power Sensors
  • R&S®NRP-Z11  R&S®NRP-Z11 Three-Path Diode Power Sensors
    Three-Path Diode Power Sensors

    Fast, accurate and packed with features for CW and modulated signals

    Measurement range: -67 dBm to +23 dBm,
    Frequency range: 10 MHz to 8 GHz,
    N connector

     

     

  • R&S®NRP-Z21 R&S®NRP-Z21 Three-Path Diode Power Sensors
    Three-Path Diode Power Sensors

    Fast, accurate and packed with features for CW and modulated signals

    Measurement range: -67 dBm to +23 dBm,
    Frequency range: 10 MHz to 18 GHz, 
    N connector

     

     

  • R&S®NRP-Z22  R&S®NRP-Z22 Three-Path Diode Power Sensors
    Three-Path Diode Power Sensors

    Fast, accurate and packed with features for CW and modulated signals

    Measurement range: -57 dBm to +33 dBm, 
    Frequency range: 10 MHz to 18 GHz, 
    N connector

     

     

  • R&S®NRP-Z23  R&S®NRP-Z23 Three-Path Diode Power Sensors
    Three-Path Diode Power Sensors

    Fast, accurate and packed with features for CW and modulated signals

    Measurement range: -47 dBm to +42 dBm, 
    Frequency range: 10 MHz to 18 GHz, 
    N connector

     

     

  • R&S®NRP-Z24 R&S®NRP-Z24 Three-Path Diode Power Sensors
    Three-Path Diode Power Sensors

    Fast, accurate and packed with features for CW and modulated signals

    Measurement range: -42 dBm to +45 dBm, 
    Frequency range: 10 MHz to 18 GHz, 
    N connector

     

     

  • R&S®NRP-Z31 R&S®NRP-Z31 Three-Path Diode Power Sensors
    Three-Path Diode Power Sensors

    Fast, accurate and packed with features for CW and modulated signals

    Measurement range: -67 dBm to +23 dBm, 
    Frequency range: 10 MHz to 33 GHz, 
    3.5 mm connector

     

     

     

Two-Path Diode Power Sensors
  • R&S®NRP-Z211 R&S®NRP-Z211 Two-Path Diode Power Sensors
    Two-Path Diode Power Sensors

    Cost-effective power measurement solution for production

    Measurement range: -60 dBm to +20 dBm, 
    Frequency range: 10 MHz to 8 GHz, 
    N connector

     

     

  • R&S®NRP-Z221  R&S®NRP-Z221 Two-Path Diode Power Sensors
    Two-Path Diode Power Sensors

    Cost-effective power measurement solution for production

    Measurement range: -60 dBm to +20 dBm, 
    Frequency range: 10 MHz to 18 GHz, 
    N connector

     

     

     

Thermal Power Sensors
  • R&S®NRP-Z51  R&S®NRP-Z51 Thermal Power Sensor
    Thermal Power Sensor

    Most accurate power measurements for reference applications and use in calibration labs

    Measurement range: -30 dBm to +20 dBm, 
    Frequency range: DC to 18 GHz,
    N connector

     

     

  • R&S®NRP-Z52  R&S®NRP-Z52 Thermal Power Sensor
    Thermal Power Sensor

    Most accurate power measurements for reference applications and use in calibration labs

    Measurement range: -35 dBm to +20 dBm, 
    Frequency range: DC to 33 GHz,
    3.5 mm connector

     

     

  • R&S®NRP-Z55  R&S®NRP-Z55 Thermal Power Sensor model .03
    Thermal Power Sensor model .03

    Most accurate power measurements for reference applications and use in calibration labs

    Measurement range: -35 dBm to +20 dBm, 
    Frequency range: DC to 40 GHz, 
    2.92 mm connector

     

     

  • R&S®NRP-Z55  R&S®NRP-Z55 Thermal Power Sensor model .04
    Thermal Power Sensor model .04

    Most accurate power measurements for reference applications and use in calibration labs

    Measurement range: -35 dBm to +20 dBm, 
    Frequency range: DC to 44 GHz, 
    2.92 mm connector

     

     

  • R&S®NRP-Z56  R&S®NRP-Z56 Thermal Power Sensor
    Thermal Power Sensor

    Most accurate power measurements for reference applications and use in calibration labs

    Measurement range: –35 dBm to +20 dBm, 
    Frequency range: DC to 50 GHz, 
    2.4 mm connector

     

     

  • R&S®NRP-Z57 R&S®NRP-Z57 Thermal Power Sensor
    Thermal Power Sensor

    Most accurate power measurements for reference applications and use in calibration labs

    Measurement range: –35 dBm to +20 dBm, 
    Frequency range: DC to 67 GHz, 
    1.85 mm connector

     

     

  • R&S®NRP-Z58   R&S®NRP-Z58 Thermal Power Sensor
     
    Thermal Power Sensor

    Most accurate power measurements for reference applications and use in calibration labs

    Measurement range: –35 dBm to +20 dBm, 
    Frequency range: DC to 110 GHz, 
    1.00 mm connector

     

     

     

Wideband Power Sensors
  • R&S®NRP-Z81 R&S®NRP-Z81 Wideband Power Sensor
    Wideband Power Sensor

    Time domain analysis and automatic pulse analysis for radar applications and universal use

    Measurement range: -60 dBm to +20 dBm, 
    Frequency range: 50 MHz to 18 GHz,
    N connector

     

     

  • R&S®NRP-Z85 R&S®NRP-Z85 Wideband Power Sensor
    Wideband Power Sensor

    Time domain analysis and automatic pulse analysis for radar applications and universal use

    Measurement range: -60 dBm to +20 dBm, 
    Frequency range: 50 MHz to 40 GHz,
    2.92 mm connector

     

     

  • R&S®NRP-Z86  R&S®NRP-Z86 Wideband Power Sensor
    Wideband Power Sensor

    Time domain analysis and automatic pulse analysis for radar applications and universal use

    Measurement range: -60 dBm to +20 dBm,
    Frequency range: 50 MHz to 40 GHz,
    2.4 mm connector

     

     

     

Average Power Sensors
  • R&S®NRP-Z91 R&S®NRP-Z91 Average Power Sensor
    Average Power Sensor

    Accurate average power measurements for EMC applications

    Measurement range: -67 dBm to +23 dBm, 
    Frequency range: 9 kHz to 6 GHz, 
    N connector

     

     

  • R&S®NRP-Z92 R&S®NRP-Z92 Average Power Sensor
    Average Power Sensor

    Accurate average power measurements for EMC applications

    Measurement range: -57 dBm to +33 dBm,
    Frequency range: 9 kHz to 6 GHz, 
    N connector

     

     

     

Level Control Sensors
  • R&S®NRP-Z28 R&S®NRP-Z28 Level Control Sensor
    Level Control Sensor

    Highly accurate signal level generation in conjunction with a signal generator

    Measurement range: -67 dBm to +20 dBm, 
    Frequency range: 10 MHz to 18 GHz, 
    N connector

     

     

  • R&S®NRP-Z98  R&S®NRP-Z98 Level Control Sensor
    Level Control Sensor

    Highly accurate signal level generation in conjunction with a signal generator

    Measurement range: -67 dBm to +20 dBm, 
    Frequency range: 9 kHz to 6 GHz, 
    N connector

     

     

     

Power Sensors for other R&S instruments
  • R&S®NRP-Z27  R&S®NRP-Z27 Power Sensor Module (for use with R&S®FSMR)
    Power Sensor Module (for use with R&S®FSMR)

    Level calibration of signal sources in conjunction with the R&S®FSMR measurement receiver

    Measurement range: -24 dBm to +26 dBm, 
    Frequency range: DC to 18 GHz, 
    N connector

     

     

  • R&S®NRP-Z37 R&S®NRP-Z37 Power Sensor Module (for use with R&S®FSMR)
    Power Sensor Module (for use with R&S®FSMR)

    Level calibration of signal sources in conjunction with the R&S®FSMR measurement receiver

    Measurement range: -24 dBm to +26 dBm, 
    Frequency range: DC to 26.5 GHz, 
    3.5 mm connector

     

     

     

Accessories
  • R&S®NRPZ-K1 R&S®NRPZ-K1 R&S®NRPV license for one R&S®NRP-Zxx power sensor
    R&S®NRPV license for one R&S®NRP-Zxx power sensor

    Convenient power measurements via PC application

     

  • R&S®NRP-Z2 
    Sensor Extension Cable

    In some cases the signal source is far away from the base unit. Therefore four different sensor extension cables are available, to get a total length of 3, 5 or 10 meters.

     

  • R&S®NRP-Z3 
    USB Adapter (active)

    R&S®NRP-Z3 active USB adapter has been developed for applications requiring external triggering of the power sensor. It also offers a separate power supply.

     

  • R&S®NRP-Z4 
    USB Adapter (passive)

    For all R&S®NRP-Z sensors. The R&S®NRP-Z4 passive USB adapter provides all basic functions, as it handles the transmission of settings and measurement data as well as the power supply of the sensor via the USB bus. Available cable lenghths: 2.0m, 0.5m, 0.15m and 1m (for panel-mount)

     

  • R&S®NRP-Z5 
    USB Sensor Hub

    R&S®NRP-Z5 can host up to 4 R&S®NRP-Z sensors. A professional trigger solution allows simultaneous internal and external triggering of all connected sensors.